Manual 0-4825 Rev. AK 8-37 TORCH DATA for AutoCut Basic
Mild Steel
300A
Air Plasma / Air Shield
Shield
Cap
Shield Gas
Distributor
Tip
35-1037 35-1283 35-1050
Plasma (Air) Shield (Air)
(ga) (in) inch (PSI) (PSI) Volts
(in)
±0.005
(ipm) (in) (sec) (in)
3/4 0.750 90 80 166 0.150 75 0.350 0.4 0.210
7/8 0.875 90 80 172 0.150 65 0.400 0.6 0.220
1 1.000 90 80 175 0.150 55 0.400 1.0 0.230
1.25 1.250 90 80 184 0.250 40 0.500 1.8 0.260
1.5 1.500 90 80 193 0.250 20 0.500 3.0 0.300
1.75 1.750 90 80 203 0.350 15 0.325
2 2.000 90 80 210 0.350 10 0.355
2 1/4 2.250 90 80 215 0.350 6 0.360
2 3/4 2.750 120 90 252 0.350 4 NA
Plasma (Air) Shield (Air)
(Bar) (Bar) Volts
(mm)
±0.1
(mm/min) (mm) (sec) (mm)
6.2 5.5 168 3.8 1830 9.3 0.5 5.4
6.2 5.5 175 3.8 1430 10.2 0.9 5.8
6.2 5.5 184 6.4 1020 12.7 1.8 6.6
6.2 5.5 196 7.1 470 7.8
6.2 5.5 209 8.7 270 8.9
6.2 5.5 222 8.7 130 9.0
8.2 6.2 253 8.7 100 6.0
BOLD TYPE
indicates maximum piercing parameters.
BOLD ITALIC
indicates edge starts only.
Edge Start
Edge Start
Edge Start
Edge Start
Edge Start
Edge Start
Edge Start
50
60 Edge Start
70
40
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
35-1044 35-1088 35-102235-1021
Shield
Retainer
Plasma Gas
Distributor
Electrode Cartridge
30
Material
Thickness
Cut Flow Rates /
Arc
Voltage
Torch
Working
Height
(mm)
20
25
Kerf Width
@ Rec.
Speed
Material
Thickness
Cut Flow Rates /
Arc
Voltage
Torch
Working
Height
Travel
Speed
Initial
Piercing
Height
Pierce
Delay
Kerf Width
@ Rec.
Speed
Cartridge
Electrode
Shield
Shield Gas
Distributor
Tip
Plasma Gas
Distributor
Shield Retainer
Art # A-07917_AC
This Art Is For Reference ONLY